(866)482-7930
www.chargetek.com
1860 Eastman Ave. #107
Ventura, CA 93003
SELECT AC INPUT VOLTAGE
GAV SERIES - AC INPUT LEAD BASED CHEMISTRY CHARGERS
GAV part numbers are easily configured. Model numbers are in the form GAw-xS yy-zz-R. R specifies options and several customization parameters such as temperature compensation, relay contacts and serial bus options. The standard product offerings are shown below and the current ratings. To order a unit with lower current simply replace the current rating of the part number shown as follows (high lint current rating) and show example. Please contact us for any variations required.
For example, the GAV-30S5-03-R denotes a standard 85-300v AC input, thirty series lead cells, (60v) and 5 amps of charging current. The suffix (R) is required for customization definition (see datasheet) but not required for standard units.
Part Numbering Scheme
GAw-xSyy-ZZ-R
w - Housing:
xS - Number of battery cells:
yy - Charging Current:
ZZ - AC Input Voltage:
V (MME) - other chassis are K(LSE), F(LPC), R(LME), D(MCF), M(SFE)
Each cell is equal to 2 volts, options are 3S, 6S, 9S, 12S, 18S, 24S, 30S, 36S and 150S
Maximum current in amps, set by xS option (lower current can be specified)
Options are:
85 - 140 VAC
01
180 - 300 VAC
02
85 - 300 VAC
03
Interactive Part Number Selector below for Standard Products
85-140V
180-300V
85-300V
Part number selection for 85-140 VAC input
Series cells/
Nominal Volts
Maximum
Current
Part
Number
6V(3S)
6V/40A
GAV-3S40-1-R
12V(6S)
12V/20A
GAV-6S20-1-R
18V(9S)
18V/15A
GAV-9S15-1-R
24V(12S)
24V/12A
GAV-12S12-1-R
36V(18S)
36V/8A
GAV-18S8-1-R
48V(24S)
48V/6A
GAV-24S6-1-R
60V(30S)
60V/5A
GAV-30S5-1-R
72V(36S)
72V/4A
GAV-36S4-1-R
300V(150S)
300V/1A
GAV-150S1-1-R
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
3S40
-
1
-
R
3
SERIES
CELLS
40 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
6S20
-
1
-
R
6
SERIES
CELLS
20 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
9S15
-
1
-
9
SERIES
CELLS
15 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
12S12
-
1
-
12
SERIES
CELLS
12 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
18S8
-
1
-
18
SERIES
CELLS
8 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
24S6
-
1
-
24
SERIES
CELLS
6 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
30S5
-
1
-
30
SERIES
CELLS
5 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
36S4
-
1
-
36
SERIES
CELLS
4 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
150S1
-
1
-
150
SERIES
CELLS
1 A
CHARGING
CURRENT
85-140 VAC
INPUT
VOLTAGE
R
R
OPTIONS
Part number selection for 180-300 VAC input
Series cells/
Nominal Volts
Maximum
Current
Part
Number
6V(3S)
6V/40A
GAV-3S40-2-R
12V(6S)
12V/20A
GAV-6S20-2-R
18V(9S)
18V/15A
GAV-9S15-2-R
24V(12S)
24V/12A
GAV-12S12-2-R
36V(18S)
36V/8A
GAV-18S8-2-R
48V(24S)
48V/6A
GAV-24S6-2-R
60V(30S)
60V/5A
GAV-30S5-2-R
72V(36S)
72V/4A
GAV-36S4-2-R
300V(150S)
300V/1A
GAV-150S1-2-R
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
3S40
-
2
-
R
3
SERIES
CELLS
40 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
6S20
-
2
-
R
6
SERIES
CELLS
20 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
9S15
-
2
-
9
SERIES
CELLS
15 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
12S12
-
2
-
12
SERIES
CELLS
12 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
18S8
-
2
-
18
SERIES
CELLS
8 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
24S6
-
2
-
24
SERIES
CELLS
6 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
30S5
-
2
-
30
SERIES
CELLS
5 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
36S4
-
2
-
36
SERIES
CELLS
4 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
150S1
-
2
-
150
SERIES
CELLS
1 A
CHARGING
CURRENT
180-300VAC
INPUT
VOLTAGE
R
R
OPTIONS
Part number selection for 85-300 VAC input
Series cells/
Nominal Volts
Maximum
Current
Part
Number
6V(3S)
6V/40A
GAV-3S40-3-R
12V(6S)
12V/20A
GAV-6S20-3-R
18V(9S)
18V/15A
GAV-9S15-3-R
24V(12S)
24V/12A
GAV-12S12-3-R
36V(18S)
36V/8A
GAV-18S8-3-R
48V(24S)
48V/6A
GAV-24S6-3-R
60V(30S)
60V/5A
GAV-30S5-3-R
72V(36S)
72V/4A
GAV-36S4-3-R
300V(150S)
300V/1A
GAV-150S1-3-R
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
3S40
-
3
-
R
3
SERIES
CELLS
40 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
6S20
-
3
-
R
6
SERIES
CELLS
20 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
9S15
-
3
-
9
SERIES
CELLS
15 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
12S12
-
3
-
12
SERIES
CELLS
12 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
18S8
-
3
-
18
SERIES
CELLS
8 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
24S6
-
3
-
24
SERIES
CELLS
6 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
30S5
-
3
-
30
SERIES
CELLS
5 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
36S4
-
3
-
36
SERIES
CELLS
4 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
GAV
-
G = LEAD
A = AC INPUT
V = MME
PART NUMBER
150S1
-
3
-
150
SERIES
CELLS
1 A
CHARGING
CURRENT
85-300 VAC
INPUT
VOLTAGE
R
R
OPTIONS
Versatile AGM/SLA/flooded/lead based
industrial battery charger
The GAV product line is designed for applications requiring AC input. This series is especially suited for alternative energy power sources including fuel cell, solar and wind power, on-board vehicle applications, and many other systems. The standard AC input range is 85-140VAC. However, we offer an extended input/output range up to 300VAC. The GAV series is available in both waterproof and fan cooled versions. User defined optional relay signal contacts are available upon request.
MME PACKAGE
© 2022 Chargetek, Inc.
1860 Eastman Ave. #107
Ventura, CA 93003
p: (866)482-7930 • f: (805)650-7936
email: sales@chargetek.com
Product Overview